CVE-2021-22681: Rockwell Multiple Products Insufficient Protected Credentials Vulnerability
Multiple Rockwell products contain an insufficient protected credentials vulnerability. Studio 5000 Logix Designer software may allow a key to be discovered. This key is used to verify Logix controllers are communicating with Rockwell Automation design software. If successfully exploited, this vulnerability could allow an unauthorized application to connect with Logix controllers. To leverage this vulnerability, an unauthorized user would require network access to the controller.
Overview
Rockwell Automation Logix controllers use a cryptographic key to verify that only legitimate Studio 5000 Logix Designer or RSLogix 5000 software is communicating with them. That key is insufficiently protected within the design software, allowing an attacker who obtains it to build an unauthorized application that presents the key and authenticates to the controller as if it were legitimate Rockwell software. Affected controllers span the CompactLogix, ControlLogix, DriveLogix, GuardLogix, and SoftLogix families, and the vulnerability exists across RSLogix 5000 versions 16 through 20 and Studio 5000 Logix Designer version 21 and later.
Vulnerability details
Affected vendor
Rockwell
Affected product
Multiple Products
Weakness type (CWE)
CWE-522
CWE-522 describes credentials or keys that are stored or transmitted in a form that allows recovery by an unauthorized party. In this case, a static cryptographic key embedded in Rockwell design software serves as the sole trust anchor between the software and Logix controllers. Because the key is insufficiently protected within the software package, an attacker who obtains a copy of Studio 5000 Logix Designer or RSLogix 5000 can extract the key through analysis of the software. Once extracted, the key can be reused in a crafted application targeting any Logix controller that accepts it.
An attacker who has extracted the key sends authentication traffic to a Logix controller over the network, presenting the key in a crafted application that mimics legitimate Rockwell design software. The controller, having no way to distinguish the unauthorized application from genuine software, grants access. The preconditions are network access to the target controller and the ability to obtain and analyze a copy of the Rockwell design software, which is commercially available. Successful exploitation gives the attacker authenticated access to industrial controllers, allowing them to interact with programmable logic, potentially alter control logic, or disrupt industrial processes.
Severity and impact
9.8
Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality impact
High
Integrity impact
High
Availability impact
High
Exploitation status
This vulnerability is confirmed as actively exploited in the wild — it is listed in CISA's Known Exploited Vulnerabilities (KEV) catalog.
Known ransomware campaign use
Unknown
Detection and monitoring
- Monitor Logix controller connection logs for sessions originating from hosts that are not authorized engineering workstations. Connections from unexpected IP addresses or subnets that would not normally run Studio 5000 or RSLogix 5000 warrant investigation.
- Review network flow data for EtherNet/IP traffic directed at Logix controllers from hosts outside the defined OT network segment, particularly from IT network ranges or external-facing systems where design software would not be installed.
Remediation
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Federal (FCEB) remediation due date
March 26, 2026
Additional hardening
- Consult the Rockwell Automation security advisory referenced in the References section for any available firmware or software updates, as the FACTS carry no fixed-version boundary for the affected controller families or design software versions.
- Restrict network access to Logix controllers using firewall rules or managed switches so that only explicitly authorized engineering workstations can reach controller ports. Controllers should not be reachable from general IT network segments or the internet.
- Place Logix controllers in isolated OT network segments with no direct routing from corporate or internet-facing networks. Where remote access is operationally required, require it to pass through a monitored jump host or VPN with strong authentication.
- Maintain and enforce an inventory of authorized engineering workstations permitted to communicate with each controller. Periodically audit that inventory against actual network connections observed on the OT segment.
Key dates
Published (NVD)
March 3, 2021
Added to CISA KEV
March 5, 2026
Remediation deadline
March 26, 2026
Last updated
June 16, 2026
References
- https://support.rockwellautomation.com/app/answers/answer_view/a_id/1130301/~/cve-2021-22681%3A-authentication-bypass-vulnerability-found-in-logix-controllers-
- https://www.cisa.gov/news-events/ics-advisories/icsa-21-056-03
- https://nvd.nist.gov/vuln/detail/CVE-2021-22681
- https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-22681
Frequently Asked Questions
If Rockwell Multiple Products runs inside your authorization boundary, yes. CVE-2021-22681 appears on CISA's Known Exploited Vulnerabilities (KEV) catalog, and its remediation deadline of March 26, 2026 has already passed. For a FedRAMP-authorized service, an unpatched KEV inside your boundary is a finding. An overdue one is a finding your assessor and sponsoring agency can already see. Your options now are to remediate it or formally document the mitigation and the delay.
Knox does not patch your software. Remediating Rockwell Multiple Products is your responsibility under the FedRAMP shared-responsibility model. What Knox provides is the pre-authorized, single-tenant boundary to remediate within, plus continuous compliance monitoring and audit-artifact coverage to document the fix for your next assessment. The remediation work is yours to carry out; maintaining a compliant posture while you do it is not something you manage on your own.
Knox's automated continuous monitoring platform watches your environment for newly disclosed vulnerabilities and compliance issues on a continuous basis. For a CVE like CVE-2021-22681, that means exposure surfaces during ongoing monitoring rather than only when an assessor flags it at review time, giving you a materially shorter window between disclosure and detection.
Knox runs a FedRAMP-as-a-Service platform. It gives SaaS vendors a pre-authorized cloud boundary on AWS, Azure, and GCP. Your application inherits 60-80% of the required security controls. You reach FedRAMP authorization in about 90 days for roughly 90% less than the traditional $3.5M path. Book a meeting and Knox will map your path to authorization.
If CVE-2021-22681 remains unremediated, it is already a Plan of Action and Milestones (POA&M) item. A growing POA&M list is what turns a routine continuous-monitoring review into a difficult conversation with your sponsoring agency. Closing the finding out and documenting why the deadline was missed is what keeps your authorization intact and the agency relationship on solid ground.
Access Continuous Compliance
We never compromise on security. Meet with our team to discuss scope, readiness, and map your company’s accelerated path to government certification.