CVE-2026-118527: Ivanti Connect Secure Generation of Predictable Numbers or Identifiers Vulnerability
Ivanti Connect Secure contains a generation of predictable numbers or identifiers vulnerability that allows a remote authenticated attacker to upload files with attacker-controlled content to a known location on disk. This vulnerability can be chained with CVE-2026-104935 and CVE-2026-111357.
Overview
Ivanti Connect Secure writes uploaded files under predictable names, so a low-privileged authenticated user can place content they control at a path they can know in advance. On its own the impact is limited to file integrity. Ivanti reports exploitation in the wild when this flaw is chained with CVE-2026-104935 and CVE-2026-111357.
Affected releases are the 25.1 line before 25.1.1.3 and the 22.8 line before 22.8R2.6.
Vulnerability details
Affected vendor
Ivanti
Affected product
Connect Secure
Weakness type (CWE)
CWE-340
CWE-340 here appears as predictable filenames for uploaded files. When a server derives an on-disk name from guessable or fixed inputs instead of unpredictable values, the attacker does not need to discover where an upload landed. Connect Secure follows this pattern, so an ordinary upload becomes a write-to-known-path primitive. The advisory does not say which upload feature is involved, why the names are predictable, or whether existing files can be overwritten, so those details should not be assumed.
The attacker must hold valid low-privilege credentials and have network reachability to the appliance. They submit a file with content they choose and rely on the known destination path. The direct gain is limited integrity impact. Ivanti states that exploitation observed in the wild chained this flaw with CVE-2026-104935 and CVE-2026-111357, and CISA notes the same chaining. The sources do not say what the write achieves alone or how the three flaws are sequenced.
Severity and impact
4.3
Medium
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N
Attack vector
Network
Attack complexity
Low
Privileges required
Low
User interaction
None
Scope
Unchanged
Confidentiality impact
None
Integrity impact
Low
Availability impact
None
Exploitation status
This vulnerability is confirmed as actively exploited in the wild — it is listed in CISA's Known Exploited Vulnerabilities (KEV) catalog.
Known ransomware campaign use
Unknown
Detection and monitoring
- Review web and admin access logs on the appliance for upload requests from authenticated low-privilege accounts that are unusual for that user or role, then check whether the resulting files appear on disk at the expected location.
- Check the indicators in Volexity's published reporting, which the Ivanti advisory points to for the chained exploitation, and correlate any hits with authentication events for the same sessions.
Remediation
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see References) guidance and CISA’s “Forensics Triage Requirements” (see References). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Federal (FCEB) remediation due date
November 13, 2026
Additional hardening
- Upgrade Connect Secure 25.1 deployments to 25.1.1.3 or later, and 22.8 deployments to 22.8R2.6 or later. Ivanti recommends moving to the 25.1 line because 22.8 is a temporary bridge. See the vendor advisory in References.
- Restrict the appliance's user-facing and administrative interfaces to known source ranges where feasible, and disable or tighten low-privilege accounts that are unused, shared, or lack multifactor authentication, since exploitation requires valid credentials.
- Because exploitation is reported in chained attacks, treat unpatched appliances with suspicious uploads as potentially compromised. Follow the CISA forensic triage requirements, preserve logs and a disk image, and rotate credentials and secrets stored on the device before returning it to service.
Key dates
Published (NVD)
November 3, 2026
Added to CISA KEV
October 30, 2026
Remediation deadline
November 13, 2026
Last updated
November 3, 2026
References
- https://hub.ivanti.com/s/article/Security-Advisory-Ivanti-Connect-Secure-CVE-2026-104935?language=en_US
- https://www.cisa.gov/news-events/directives/bod-26-04-prioritizing-security-updates-based-risk
- https://www.cisa.gov/news-events/directives/bod-26-04-implementation-guidance-prioritizing-security-updates-based-risk
- https://nvd.nist.gov/vuln/detail/CVE-2026-118527
- https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-118527
Frequently Asked Questions
If Ivanti Connect Secure runs inside your authorization boundary, CVE-2026-118527 does affect your FedRAMP authorization. CISA lists it in the Known Exploited Vulnerabilities (KEV) catalog, and the remediation deadline of November 13, 2026 has already passed. An unpatched KEV inside the boundary is an assessor finding, and an overdue one is visible to your assessor and sponsoring agency. Remediate it now, or formally document the mitigation and the reason for the delay.
Knox does not patch your software. Under the FedRAMP shared responsibility model, remediating Ivanti Connect Secure sits with you. Knox supplies the pre-authorized, single-tenant boundary where you apply the fix, along with continuous compliance monitoring and audit-artifact coverage that support documentation of the remediation at your next assessment. You apply the patch; you do not carry the compliance work around it alone.
Knox's automated continuous monitoring platform watches your environment in real time for newly disclosed vulnerabilities and compliance issues, including KEV-listed items such as CVE-2026-118527. Exposure surfaces during ongoing monitoring rather than only when an assessor flags it at review.
Knox runs a FedRAMP-as-a-Service platform. It gives SaaS vendors a pre-authorized cloud boundary on AWS, Azure, and GCP. Your application inherits 60-80% of the required security controls. You reach FedRAMP authorization in about 90 days for roughly 90% less than the traditional $3.5M path. Book a meeting and Knox will map your path to authorization.
CVE-2026-118527 is past its November 13, 2026 deadline, so if it remains unremediated it is already a Plan of Action and Milestones (POA&M) item. A growing POA&M list turns a routine continuous-monitoring review into a difficult conversation with your agency. Closing it out and documenting why the deadline slipped keeps your authorization clean and the agency relationship intact.
Access Continuous Compliance
We never compromise on security. Meet with our team to discuss scope, readiness, and map your company’s accelerated path to government certification.