CVE-2025-25249: Fortinet Multiple Products Heap-based Buffer Overflow Vulnerability

Fortinet FortiOS, FortiSwitchManager, and FortiSASE contain a heap-based buffer overflow vulnerability that allows an attacker to execute unauthorized code or commands via specially crafted packets.

Added to the CISA KEV catalog:
September 9, 2026

Overview

FortiOS, FortiSwitchManager, and FortiSASE contain a heap-based buffer overflow in the Security Fabric interface that allows an unauthenticated remote attacker to execute arbitrary code or commands by sending specially crafted packets. Affected FortiOS versions span the 6.4 through 7.6 release lines, FortiSwitchManager covers the 7.0 and 7.2 lines, and FortiSASE specific builds are also affected. Exploitation has been observed in the wild, with post-exploitation activity including deployment of a remote access trojan identified as PivotC2.

Vulnerability details

Affected vendor
Fortinet
Affected product
Multiple Products
Weakness type (CWE)
CWE-122, CWE-787

A heap-based buffer overflow (CWE-122 / CWE-787) occurs when attacker-supplied input exceeds the bounds of a heap-allocated buffer, corrupting adjacent memory. In this case, the vulnerable processing occurs on the Security Fabric interface exposed by FortiOS and FortiSwitchManager. Because the overflow is triggered before any authentication check completes, no credentials are required. Successful memory corruption gives an attacker control over execution flow, enabling arbitrary code or command execution on the device.


An attacker sends specially crafted network packets directly to the Security Fabric interface of a reachable device. The critical precondition is that the fabric interface must be exposed and network-accessible to the attacker. Where that condition is met, exploitation requires no authentication and no user interaction. Post-exploitation activity observed in the wild includes deployment of PivotC2, a remote access trojan that provides persistent command-and-control access to the compromised FortiGate device, per the SOCRadar reporting referenced in the advisory.

Severity and impact

9.8
Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
Network
Attack complexity
Low
Privileges required
None
User interaction
None
Scope
Unchanged
Confidentiality impact
High
Integrity impact
High
Availability impact
High

Exploitation status

This vulnerability is confirmed as actively exploited in the wild — it is listed in CISA's Known Exploited Vulnerabilities (KEV) catalog.

Known ransomware campaign use
Unknown

Detection and monitoring

  • Audit per-interface configuration for fabric access enabled on internet-facing or untrusted interfaces. Any interface with fabric access enabled that is not part of a deliberate, documented Security Fabric topology is an exposure indicator worth immediate review.
  • Monitor FortiOS and FortiSwitchManager logs for unexpected process crashes, daemon restarts, or memory fault events on the Security Fabric service, which may indicate failed or successful exploitation attempts against the heap overflow.
  • Look for anomalous outbound connections or new persistent processes originating from FortiGate devices following inbound traffic to the Security Fabric port, as post-exploitation PivotC2 activity would produce command-and-control beaconing not present in a healthy baseline.

Remediation

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see References) guidance and CISA’s “Forensics Triage Requirements” (see References). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Federal (FCEB) remediation due date
September 12, 2026

Additional hardening

  • Upgrade FortiOS to 7.6.4 or later (7.6 line), 7.4.9 or later (7.4 line), or 7.2.12 or later (7.2 line); upgrade FortiSwitchManager to 7.2.7 or later (7.2 line) or 7.0.6 or later (7.0 line). See References for full version guidance including FortiSASE.
  • As an immediate compensating control, remove fabric access from every interface that does not require it. The Siemens advisory explicitly names this as the vendor-recommended workaround: for each interface, disable the fabric access setting.
  • Restrict network access to the Security Fabric interface using firewall rules or ACLs so that only known, trusted peer devices in the Security Fabric topology can reach the relevant port. Internet-facing exposure of this interface should be treated as critical risk.
  • Conduct forensic triage on any FortiOS or FortiSwitchManager device that was running an affected version with fabric access exposed, checking for unexpected processes, modified files, or outbound connections consistent with post-exploitation RAT activity.

Key dates

Published (NVD)
January 13, 2026
Added to CISA KEV
September 9, 2026
Remediation deadline
September 12, 2026
Last updated
September 10, 2026

References

Frequently asked questions

Does CVE-2025-25249 affect my FedRAMP authorization?

If Fortinet Multiple Products runs inside your authorization boundary, yes. CVE-2025-25249 appears in CISA's Known Exploited Vulnerabilities (KEV) catalog, and its remediation deadline of September 12, 2026 has already passed. For a FedRAMP-authorized service, an unpatched KEV in your boundary is a finding. An overdue one is a finding your assessor and sponsoring agency can see right now. Your options are to remediate it immediately or formally document the mitigation and the delay.

How does Knox help me handle CVE-2025-25249?

Knox does not patch your Fortinet Multiple Products deployment. That remediation is yours to carry out under the FedRAMP shared-responsibility model. What Knox provides is the pre-authorized, single-tenant boundary to remediate within, along with continuous compliance monitoring and audit-artifact coverage that document the fix for your next assessment. The work of applying the patch is entirely yours; managing your compliance posture while you do it is not something you have to handle alone.

How does Knox's monitoring help with vulnerabilities like this?

Knox's automated continuous monitoring platform watches your environment for newly disclosed vulnerabilities and compliance issues on an ongoing basis. For a CVE like CVE-2025-25249, that means exposure surfaces during continuous monitoring rather than waiting until an assessor flags it at a scheduled review.

How do I get FedRAMP authorized with Knox?

Knox runs a FedRAMP-as-a-Service platform. It gives SaaS vendors a pre-authorized cloud boundary on AWS, Azure, and GCP. Your application inherits 60-80% of the required security controls. You reach FedRAMP authorization in about 90 days for roughly 90% less than the traditional $3.5M path. Book a meeting and Knox will map your path to authorization.

CVE-2025-25249's remediation deadline of September 12, 2026 has passed. What happens now?

If CVE-2025-25249 remains unremediated, it is already a Plan of Action and Milestones (POA&M) item. A growing POA&M list is precisely what turns a routine continuous-monitoring review into a difficult conversation with your sponsoring agency. Closing the finding out and documenting why the deadline was missed is what keeps your authorization clean and the agency relationship on stable ground.

Ready to achieve FedRAMP authorization in 90 days or less?

Schedule a meeting to discuss scope, parse readiness, and map your company’s accelerated path to FedRAMP authorization.